Exide Star
Features
Advance Microcontroller Based
LED Display for User Interface
Dual Stage of Charging
Auto Smart Protections
Pure Sine Wave Output Wave Shape Suitable for Mains Low Voltage Operation
Wide Range of Mains Input Voltage for Battery Charging i.e. 90V - 300V AC
Technical Specifications of Exide Inverterz Star
Description | STAR 12V 650VA | STAR 12V 850VA | STAR 12V 1050VA | STAR 24V 1450VA |
---|---|---|---|---|
Output Voltage at No Load | 220V ± 7V AC | |||
Output Frequency | 50Hz ± 1Hz | |||
Output Wave Form | Pure Sine Wave | |||
Nominal Battery Voltage | 12V DC | 24V DC | ||
Battery Low Cut Off | 10.5V ± 0.2V DC | 21.0V ± 0.4V DC |
Charging Mode
Model | STAR 12V 650VA | STAR 12V 850VA | STAR 12V 1050VA | STAR 24V 1450VA |
---|---|---|---|---|
Maximum Charging Current (NC) | 11Amps ± 1Amp | 12Amp ± 1Amp | 13Amp ± 1Amp | 12Amp ± 1Amp |
Maximum Charging Current (HC) | 15Amps ± 1Amp | 17Amp ± 1Amp | 18Amp ± 1Amp | 17Amp ± 1Amp |
Boost Charging Voltage | 14.4V ± 0.2V DC | 28.8V ± 0.4V DC | ||
Trickle Charging Voltage | 13.7V ± 0.2V DC | 27.4V ± 0.4V DC | ||
Charging Current at 120V Mains Input | 8-10 Amp Charging Current* | |||
Charging Over Time Mains to Back-up (@ UPS Mode) | ≤ 10 msec | |||
Charging Over Time Back-up to Mains (@ UPS Mode) | ≤ 10 msec | |||
Input Voltage Range (@ UPS Mode) | 180V – 270V ± 10V AC | |||
Change Over Time Mains to Back-up (@ Normal Mode) | ≤ 40 msec | |||
Change Over Time Back-up to Mains (@ Normal Mode) | ≤ 10 msec | |||
Input Voltage Range (@ Normal Mode) | 90V – 300V ± 10V AC |